Solid State Logic System T Broadcast Console

Solid-State-Logic-System-T-Broadcast-Console-product

產品使用說明

All Rights reserved under International and Pan-American Copyright Conventions SSL and Solid State Logic are ® registered trademarks of Solid State Logic System T™, Network IO™, Netbridge™, SuperAnalogue™, Eyeconix™ are ™ trademarks of Solid State Logic Dante™ and Audinate™ are ® registered trademarks of Audinate Pty Ltd      Avid® and Pro Tools® are trademarks or registered trademarks of Avid Technology, Inc. or its subsidiaries in the United States and/or other countries. Mackie Control® and HUI® are registered trademarks of LOUD Technologies Inc. Dolby® and Dolby Atmos™ are trademarks or registered trademarks of Dolby Laboratories Licensing Corporation. All other product names and trademarks are the property of their respective owners and are hereby acknowledged.

No part of this publication may be reproduced in any form or by any means, whether mechanical or electronic, without the written permission of Solid State Logic, Oxford, OX5 1RU, England. As research and development is a continual process, Solid State Logic reserves the right to change the features and specifications described herein without notice or obligation.  Solid State Logic cannot be held responsible for any loss or damage arising directly or indirectly from any error or omission in this manual. PLEASE READ ALL INSTRUCTIONS, PAY SPECIAL HEED TO SAFETY WARNINGS.

電&OE

文件修訂歷史

  • V1.2 Initial release EA November 2025
  • V1.3 Re-uploaded file with new checksum EA November 2025

介紹
System T installations typically include one or many SSL surfaces, Tempest Engines, and Network I/O units. This software release comprises control surface software and Tempest Engine card firmware updates. To identify the current software version running on any console(s), go to Menu>Setup>Service>Admin>About. Updating to V4 directly from V2 software is not supported; a V3.0 or later version must be already installed first due to significant changes to the console’s embedded operating system. V3 and later software require a one-time OS licence to update from V2. Contact support@solidstatelogic.com for further information on licensing. Refer to the V4.2.13 Features Release Notes for further information before installation.
請注意: This update requires any manual IP address settings for the console’s interfaces to be verified/re-entered after the update. Ensure all fixed IP addresses are recorded before commencing this update, including the S400. If this includes S500 Meter Bridge Processors, refer to the Restore Fixed IP Address to Meter Bridge Processor section in this document for further information.

要求

  • 控制台至少運行 V3.0.x 軟體
  • 空白 USB 隨身碟 – 16GB 或更大 – 用於平面安裝映像
  • 用於備份控制台的附加 USB 驅動器 files
  • USB鍵盤
  • USB AB 線
  • Windows PC and Quartus Prime Programmer software [prev. version dependent]
  • System T 4.2.13 install image file
  • Rufus V3.5 software installed on a Windows PC
  • 但丁控制器
  • Network I/O V4.5 Package if not already updated
  • WinMD5校驗與驗證工具[可選]
  • 團隊View呃登入憑證 [可選]
  • TCA V4.2.13 Installer [Optional]
  • Basic hand tools – PZR driver, 2mm hex driver, and M4 tile puller as originally supplied with console

創建 USB Flat 安裝程序

  1. 下載軟體鏡像 file 使用上面的連結。
  2. [可選] 對下載的檔案執行校驗和 file using WinMD5. The checksum value is: 45c56253be2248ea09a11e78dad4b730
  3. 下載 Rufus 3.5 並執行 .exe 應用程式。 在啟動選擇中選擇正確的 iso 映像,選擇正確的設備,然後確保分區方案設定為 GPT。
  4. Enter a suitable Volume label so that the drive can be identified in the future, i.e., System TV4.2.13 Flat Installer.
  5. Select Start and confirm that you wish to erase all data on the USB drive by clicking OK. Rufus will now partition your device and copy the files。 (USB2大約需要40分鐘,USB3大約需要5分鐘)
  6. Once the process is complete, there will be an ‘Important notice about Secure Boot’. This can be ignored – press Close. The USB Flat Installer is now ready to be used.Solid-State-Logic-System-T-Broadcast-Console-fig (1)

安裝控制台軟體
The same USB Flat Installer is used to update the Front Panel Processor (FPP) in all System T console variants, as well as the Meter Bridge Processor (MBP) in S500/S500m surfaces. The control surface assemblies must be updated in the order detailed below. Failure to follow this order can break communication between the FPP and MBP assemblies, for examp勒。

準備和更新訂單

  1. 系統備份 files – 插入備用 USB 隨身碟(不是 Flat Installer),然後導覽至選單 > 設定 > 服務 > 管理以使用備份資料功能
  2. Make an additional record of all fixed IP addresses in use on the FPP, MBP, Member, and Remote surfaces
  3. 載入空白節目file 模板 – 清除路由並放棄任何所有權
  4. 關閉控制台電源
  5. Remove any external screen connections [S300/S400 only]
  6. 更新電錶橋處理器軟體 [S500/S500m 帶電錶橋]
  7. Manually restore fixed IP address for MBP [not applicable if set to DHCP]
  8. Update additional Member FPPs where applicable; User 2 and 3 positions in larger surfaces and/or remote TCR Member surfaces, etc.
  9. Update the main console FPP software
  10. Manually restore fixed IP addresses for FPP Main and Members
  11. 自動 Tempest Engine OCP 軟體更新
  12. Update Control Surface tiles and assembly firmware from the GUI, where applicable
  13. Program the Tempest Engine 120 card using Quartus Prime, where applicable
  14. Other updates, including TCA Remotes/Backup Surfaces and TeamViewer re-installation, were relevant

關於 USB 安裝程式連接的重要說明
It is possible that the USB flat installer will not be detected when connected via ports on the console surface. Should this be the case, connect directly to the processor motherboard/carrier board USB ports. This means locating the bay position in which the processor is located and temporarily removing the relevant touch screen or surface tile to insert the USB, seating them back in their usual position while the installation process completes.

Important Note on Boot Menu Display
F7 on an external keyboard will launch the boot menu to select a boot device. In some cases, the menu will not appear from power on, and a software restart of the FPP is required by pressing the Ctrl-Alt-Del key combination before tapping F7 again.

更新儀表橋接器處理器
僅適用於具有米橋的 S500/S500m 表面。

  1. Connect the USB install stick to an available MBP USB port (internal if not detected externally). Connect a keyboard to the MBP USB connection at the rear of the console.
  2. Power on the console and tap F7 on the keyboard continuously to open the boot menu. Should the boot menu not appear, press Ctrl-Alt-Del then F7 again.
  3. Use the Up/Down arrow keys on the keyboard to select the UEFI device (USB Flat Installer), then press Enter. If there are two devices listed as per the screenshot below, select the upper UEFI option. The console will now boot from the USB Flat Installer.Solid-State-Logic-System-T-Broadcast-Console-fig (2)
  4. The screen will appear blank for approximately two minutes while the OS installer starts. When the Command Prompt ‘Solid State Logic Tempest Installer’ appears, choose option 1: “Install image and KEEP user data.” This retains the existing MBP configuration.Solid-State-Logic-System-T-Broadcast-Console-fig (3)
  5. . Progress will be shown at the bottom of the window as a percentage,大約需要五分鐘才能完成。 完成後,將顯示訊息“您已刪除所有可移動媒體嗎?” 會出現。 從處理器上實際移除 USB 扁平安裝棒,然後按鍵盤上的 Y 繼續。
  6. The ‘Please press 1 to REBOOT’ will now display. Follow the on-screen instructions and press number 1 on the keyboard to reboot.
  7. Windows Setup will begin with various progress screens and automatic restarts during this process. 請注意: It may look like the installer is not active during this time. Be patient and DO NOT power cycle the console during this process. When complete, the Meter Bridge will show a blank meters layout.
  8. If using DHCP for the MBP connection to FPP, the MBP update is complete. If using a fixed IP address on the MBP, follow the steps on the next page to manually restore this.

Restore Fixed IP Address to Meter Bridge Processor. Applicable only to S500/S500m surfaces with Meter Bridge using a fixed IP address. If using DHCP, proceed to the next section (Update FPP). \

  1. Power off the console, then boot from the Flat Install USB again by pressing the F7 key. When presented with the list of options, select 5) Go to command prompt
  2. At the command prompt, type notepad and press enter to launch the application, then go to File>Open and change the file type dropdown from Text Document to All Files.
  3. Navigate to the console’s Data directory by first selecting ThisPC, then identifying the relevant drive; Data is D:\ under normal operating conditions, but booting from the flat installer will typically push this to F:\.
  4. Within the Data drive, open the SSL/TempestBroadcast/ConfigFiles directory and locate the AdapterIpSettings_XXXXXXXXXXXX.xml files. There will be two of these – open both of them in separate NotePad windows: AdapterIpSettings_{XXXXXXXX-XXXX-XXXX-XXXX-XXXXXXXXXXXX}.xml = previous config file with fixed IP address setting AdapterIpSettings_XXXXXXXXXXXX.xml = new config file with DHCP setting
  5. Note the new file comprises the following line: true. Copy these lines from the old file – where ‘x’ is the fixed value – then paste over the line quoted above in the new file. Leave all other lines intact, then save the new file. false x.x.x.x x.x.x.x x.x.x.x x.x.x.xSolid-State-Logic-System-T-Broadcast-Console-fig (4)

更新前面板處理器
Your System T console surface may have more than one FPP for multi-operational positions or due to the large size of the surface. If you are not able to determine this, contact your local SSL Support Office. Additional FPPs in positions 2 and 3, etc., must be updated before the host FPP in position 1. This includes any remote TCR or other console surfaces configured as Members. The update instructions are the same for each:

  1. Connect the USB install stick to an available FPP USB port (internal if not detected externally). Connect a keyboard to any available FPP USB connection.
  2. Power on the console and tap F7 on the keyboard continuously to open the boot menu. Should the boot menu not appear, press Ctrl-Alt-Del then F7 again.
  3. Use the Up/Down arrow keys on the keyboard to select the UEFI device (USB Flat Installer), then press Enter. If there are two devices listed as per the screenshot below, select the upper UEFI option. The console will now boot from the USB Flat Installer.Solid-State-Logic-System-T-Broadcast-Console-fig (5)
  4. The screen will appear blank for approximately two minutes while the OS installer starts. When the Command Prompt ‘Solid State Logic Tempest Installer’ appears, choose option 1: “Install image and KEEP user data.” This retains the existing FPP configuration.Solid-State-Logic-System-T-Broadcast-Console-fig (6)
  5. 進度將以百分比形式顯示在視窗底部tage, taking approximately five minutes to complete. Upon completion, the message ‘Have you removed all removable media?’ will appear. Physically remove the USB Flat Installer stick from the processor, then press Y on the keyboard to progress.
  6. The ‘Please press 1 to REBOOT’ will now display. Follow the on-screen instructions and press number 1 on the keyboard to reboot.
  7. Windows Setup will begin with various progress screens, and automatic restarts will happen during this process.
    請注意: It may look like the installer is not active during this time. Be patient and DO NOT power cycle the console during this process. When complete, the console will boot into the usual Front Panel display/console GUI.
  8. Navigate to the Menu>Setup>Service>Update page to confirm the Current Version for the Control Software is showing V4.2.13.67660
  9. Repeat the above steps for any other FPPs fitted to the console surface (Position 3, then position 1 FPP last, for example)。
  10. Once the final FPP update has been completed, navigate to Menu>Setup>Service>Network and manually restore fixed IP address configuration – fixed IP addresses will have been reset to DHCP during this update procedure due to necessary changes in the underlying changes to adapter configuration files.
  11. 再次重新啟動控制台,以便它讀取其控制台名稱 file,在選單>設定>選項>系統中可見。

T-Engine OCP 軟體(自動)
此過程是自動的,將在主 FPP 啟動到新軟體後三分鐘內發生。 選單>設定>服務>更新將在任何已連接的 T-Engine 旁邊顯示“自動更新待定”,然後顯示“錯誤:連線遺失”。 這是下載程式碼和 T-Engine 自行重啟的結果。 連線將很快重新建立。 請參閱“軟體和韌體版本超過”view' 本文檔後面的表格用於確認顯示了正確的版本。

更新曲面組件
The Menu>Setup>Service>Update page lists all connected control surface tiles and internal card assemblies (on each FPP, if multiple are fitted). Required updates are automatically prompted and can be completed in any order. Press and hold the active Update button to start the firmware update. The screen and surface will be locked out while the update is in progress. Control surface tiles will automatically restart and reconnect upon completion. Repeat the process for all required tiles/assemblies

T-Engine 62D120 卡韌體更新
Unchanged since V4.0.15. Updating from earlier versions requires firmware UID 500877 for the 62D120 PCIe Audio fitted to each T-Engine. This is programmed using the Quartus Prime Programmer software:

  1. Connect a USB memory stick to the console, navigate to Menu>Setup>Service Update, then press and hold the Update button next to the listed 62D120 card. This transfers a .pof firmware file 到 U 盤。
  2. 下載 Quartus Prime 並將其安裝到 Windows PC。
  3. T-Engine 通電後,將 USB AB 連接線從電腦連接到後部 62D120 卡(標記為 AUDIO I/F)上的 PROG 連接埠。
  4. Launch Quartus Prime. Check Hardware Setup lists a connected USB-Blaster device. If not, follow this guide to complete the installation/association of programmer drivers. Once confirmed/resolved, return to the main application window.
  5. In the Mode dropdown list, select JTAG (if not set by default), then press the Auto Detect button on the left side of the application window.
  6. 將出現一個對話框,顯示設備清單。 選擇 5CGXFC9E7 設備並按一下“確定”。 這通常是清單中的最後一個條目。
  7. A graphical representation of three devices will be shown. Click on the CFI_128Mb chip icon, then select\ Change File 從左側的按鈕。
  8. 在結果中 file 瀏覽器視窗中,開啟 MADIMax_5CGXFC9E7F31C8N_D120.pof file 從 USB 記憶棒。 資料夾路徑為 SSL\SystemT\Firmware\D120。
  9. In the main application window, tick the boxes for Program/Configure and Verify, then click Start. A progress bar is shown in the top-right corner. Updates take between 5 and 10 minutes, at which point 100% Complete will be shown. Should there be an error/failure reported, check settings, then re-attempt.
  10. Once completed, successfully repower the T-Engine to load the programmed code. Check that the correct firmware UID is shown in the console’s Update menu. Repeat steps if there is a second T-Engine.Solid-State-Logic-System-T-Broadcast-Console-fig (7) Solid-State-Logic-System-T-Broadcast-Console-fig (8)

附加 T-Engine/HC 橋接卡
For 62D124 and 62D151 T-Engine/HC Bridge cards, firmware remains unchanged since V3.0.14. Confirm versions listed in Menu>Setup>Service>Update are current compared to the Software and Firmware Version Overview 本文檔後面的表。 如果 62D120 之外還有任何卡片不是最新的,請參閱先前的 V3.0.x 安裝說明文件或聯絡您當地的 SSL 支援辦公室以取得進一步指導。

網路 I/O 更新
The Network I/O V4.5 Package includes new SSL and Dante firmware for some Network IO devices, if not updated as part of a previous software release. Refer to the Install Notes included in the V4.5 release as well as the firmware table in this document for further information.

團隊View安裝
如果使用,團隊Viewer will need to be reinstalled and configured after this update has been applied. This requires the Admin Access function to be unlocked by a four-digit access code in Menu>Setup>Service>Admin. Contact your local SSL Support Office for an access code. For full details on the installation process, refer to System T Application Note 021.

Tempest Control App (TCA)
From V4.0 onwards, Tempest Control App (TCA) brings the full feature-set of System T into a software application with direct control of Tempest Engines. Replacing TSOLSA, the software will continue to be available free-of-charge for Offline showfile configuration and Remote connectivity to external control surfaces. With the optional Online licence, it becomes possible for TCA to directly control Tempest Engines and Dante networks. This provides new system design possibilities, including flypack, virtual, and backup control solutions for both new and existingcustomers. Download the installer package via the Support site, which includes TCA-specific installation notes that should be referred to. Update any client machines to V4.2.13 TCA software, matching the console. It is not possible to connect TCA/T-SOLSA clients that are running an older version of the software.
軟體授權協議
By using this Solid State Logic product and the software within it, you agree to be bound by the terms of the relevant End User Licence Agreement (EULA), a copy of which can be found at https://www.solidstatelogic.com/legal. You agree to be bound by the terms of the EULA by installing, copying, or using the software. Written Offer for GPL and LGPL Source Code. Solid State Logic uses Free and Open Source Software (FOSS) in some of its products, with corresponding open source declarations available at https://www.solidstatelogic.com/legal/general-end-user-license-agreement/free-open-source-software-documentation。 某些 FOSS 許可證要求 Solid State Logic 向接收者提供與根據這些許可證分發的 FOSS 二進位檔案相對應的原始程式碼。 如果此類特定授權條款使您有權獲得此類軟體的原始程式碼,Solid State Logic 將在我們分發產品後三年內,根據書面請求透過電子郵件和/或傳統紙本郵件向任何人提供適用的來源代碼透過 CD-ROM 或 USB 隨身碟,只需支付 GPL 和 LGPL 允許的運輸和媒體費用即可支付象徵性費用。 請將所有詢問寄至: support@solidstatelogic.com

軟體和韌體版本超過view
粗體數字表示此版本的新版本。

控制台和 Tempest 引擎軟體和韌體Solid-State-Logic-System-T-Broadcast-Console-fig (9)

其他控制台和軟體(SSL 測試摘要)
For System T and SSL Live consoles in a shared network environment, all consoles should be updated at the same time. Other software apps and tools on the network may also have dependencies. To assist with updates to SSL, publish a list of versions tested alongside each console release. Audinate manages forward and backward compatibility for Dante implementations and applications. Other Audinate software versions will work with the console software releases. This list documents what was tested at SSL.Solid-State-Logic-System-T-Broadcast-Console-fig (10)

網路 I/O 應用Solid-State-Logic-System-T-Broadcast-Console-fig (11)

The legacy Dante Firmware Updater is not supported for this release and is incompatible with Brooklyn 3 modules

網路 I/O 設備Solid-State-Logic-System-T-Broadcast-Console-fig (12)Solid-State-Logic-System-T-Broadcast-Console-fig (13)

請注意: Dante 韌體版本可在 Dante Controller>Device 中查看 View>製造商資訊>產品版本下的狀態。 配備 Brooklyn 2 或 3 變體的設備在表中分別以「Bk2」和「Bk3」表示。

常問問題

Q: Can I update directly from V2 software to V4?

A: No, updating directly from V2 to V4 is not supported. You must have V3.0 or later installed first.

Q: What should I do if the USB installer does not detect when connected via console ports?

A: Connect directly to the processor motherboard/carrier board USB ports as instructed in the manual.