科聯標誌

CITADEL MESH
MIDI TOWER CASE

KOLINK ANL-INT Citadel Mesh Midi Tower Case

使用者手冊

配件包內容

KOLINK ANL-INT Citadel Mesh Midi Tower Case - Fig 1

面板拆卸

前/側面板拆卸

  • Take off the front panel by pulling carefully from the bottom of the panel
  • Remove the left side panel by pulling on the pull tab & swinging the door outwards, then lift off the hinges at the back of the case.
  • Remove the right side pane by removing the two rear thrum screws and sliding the panel backwards

KOLINK ANL-INT Citadel Mesh Midi Tower Case - Fig 2

MOTHERBOARD INSTALLA

主板安裝

  • Align your motherboard with the chassis to locate where the stand-offs should be installed Once done, remove the motherboard and fasten stand-offs accordingly
  • Insert your motherboard I/O plate into the cutout at the rear of the case
  • Place your motherboard into the chassis, making sure the rear ports fit into the I/O plate
  • Use the provided motherboard screws to attach your motherboard to the chassis

KOLINK ANL-INT Citadel Mesh Midi Tower Case - Fig 3

電源安裝

電源安裝

  • Place PSU in the bottom rear of the case, within the PSU shroud
  • 對齊孔並用螺絲固定

KOLINK ANL-INT Citadel Mesh Midi Tower Case - Fig 4

顯卡/PCI-E 卡安裝

顯卡/PCI-E 卡安裝

  • 必要時卸下後 PCI-E 插槽蓋(取決於卡的插槽大小)
  • Carefully position and slide your PCI-E card into place, then secure with the add-on card screws supplied If mounting vertically, attach the vertical GPU mount to the PSU shroud, attach the Klink PCI-E Riser Cable (Sold separately). remove the rear PCI-E slot covers and put the card into place, mounting to the PCI-E Riser cable mount securely
  • Remember to attach the other end of the PCI-E Riser cable to your motherboards PCI-E 16x slot

KOLINK ANL-INT Citadel Mesh Midi Tower Case - Fig 5

2.5″ SDD INSTALLATION (F)

2.5英寸SSD安裝(正面)

  • Align your drive over the screw holes and secure with screws from the rear

KOLINK ANL-INT Citadel Mesh Midi Tower Case - Fig 6

2.5 英寸 SDD 安裝 (R)

2.5 英寸 SSD 安裝(背面)
Place your SSD on top of the HDD bracket and secure with screws

KOLINK ANL-INT Citadel Mesh Midi Tower Case - Fig 7

3.5英寸硬盤安裝

3.5英寸硬盤安裝

  • Slide the drive into/onto the 3,5″ bay at the rear of the case
  • Secure the drive on the both sides using the provided screws and hand tighten

KOLINK ANL-INT Citadel Mesh Midi Tower Case - Fig 8

頂部風扇安裝

頂部風扇安裝

  • Remove the dust filter from the top of the case
  • Align your fan(s) to the screw holes on the top of the chassis and secure with screws
  • Replace your dust filter once secured

KOLINK ANL-INT Citadel Mesh Midi Tower Case - Fig 9

前/後風扇安裝

前/後風扇安裝

  • Align your fan to the screw holes on the chassis and secure with screws

KOLINK ANL-INT Citadel Mesh Midi Tower Case - Fig 10

水冷散熱器安裝

水冷散熱器安裝

  • 將風扇固定在散熱器上,然後用外部螺釘將散熱器固定在機箱內

輸入輸出面板安裝

輸入輸出面板安裝
Carefully check the labelling of each connector from the 1/0 panel to identify their function
Cross reference with the motherboard manual to locate where each wire should be installed, then secure one at a time, Please ensure they are installed in the correct polarity to avoid non-function or damage

科聯標誌

文件/資源

KOLINK ANL-INT Citadel Mesh Midi Tower Case [pdf] 使用者手冊
ANL-INT, ANL-INT Citadel Mesh Midi Tower Case, Citadel Mesh Midi Tower Case, Mesh Midi Tower Case, Midi Tower Case, Tower Case

參考

發表評論

您的電子郵件地址不會被公開。 必填欄位已標記 *