Tecmojo 12U Open Frame Network Rack

Tecmojo 12U Open Frame Network Rack Instruction Manual

Comprehensive guide for assembly, installation, and usage of your Tecmojo 12U Open Frame Network Rack.

產品結束view

The Tecmojo 12U Open Frame Network Rack is designed for organizing IT and AV equipment in various environments. It offers versatile mounting options, including floor standing and wall mounting, and is constructed from durable cold rolled steel to ensure stability and high load-bearing capacity.

主要特點

  • Powerful Load-bearing: Constructed from durable cold rolled steel. Wall-mounted capacity of 130lbs, ground-mounted up to 260lbs.
  • Considerate Designs: Open-frame layout with a top panel for added space, anti-slip shelf stops, and compatible racks for stacking and expansion.
  • 配件齊全: Includes a 12U open frame server rack, two ventilated shelves, four shelf stops, four velcro straps, and a set of equipment mounting screws.
  • 多功能應用: Ideal for space-efficient multi-device setups in warehouses, retail, classrooms, offices, and more. Suitable as an AV Rack or IT Rack.
  • 輕鬆設定: Comes with hardware, a comprehensive manual, mounting hole drilling template, and an online assembly video to simplify setup.

包裝內容

組裝前請確認所有零件齊全。

Tecmojo 12U Open Frame Network Rack components including shelves, screws, and tools

Image: All components included in the Tecmojo 12U Open Frame Network Rack package.

  • 1 x 12U Open Frame Server Rack (Main Frame Components)
  • 2 x 1U 14-inch Ventilated Rack Shelves
  • 4 x Shelf Stops
  • 4 x 尼龍搭扣帶
  • 1 x Set of Equipment Mounting Screws (10-32 Screw x 25)
  • 1 x L Wrench
  • 4 x Rack Shelf Back Supports
  • 4 x M5*30 Wall Mounting Screws
  • 1 x Mounting Hole Drilling Template
  • 1 x 使用說明書

規格

產品尺寸20.15 英吋深 x 20.47 英吋寬 x 21.02 英吋高(51.2 公分深 x 52.0 公分寬 x 53.4 公分高)
物品重量28.6 磅(12.97 公斤)
機架單元12U
材料合金鋼(冷軋鋼)
顏色黑色的
Ground-Mounted Load Capacity最多 260 磅(117.9 公斤)
Wall-Mounted Load Capacity最多 130 磅(59 公斤)
框架類型Open Frame, Wall Mount or Floor Standing
遵守EIA/ECA-310-E Compliant

組裝和設置

Follow these steps to assemble your Tecmojo 12U Open Frame Network Rack. An electric driver is recommended for faster assembly.

第二步:組裝主機架

Attach the front and rear beams to the side frames using the M6 Butter Head Hex Screws. Ensure the front and rear beams are installed in the same direction, with the "Tec Mojo" logo facing outwards on the front beam.

Video: Visual guide for assembling the main frame of the Tecmojo network rack.

Diagram showing the dimensions of 12U, 16U, and 20U racks, and detailed specifications for the 12U rack.

Image: Detailed dimensions and specifications of the Tecmojo 12U rack, including width, height, and depth.

Step 2: Install the Top Cover

Place the top cover onto the assembled frame and secure it with the M4.4 screws. The top cover adds rigidity and provides cable pass-through grommet holes for organized cable management.

Close-up of the top cover with grommet holes for cable pass-through and clearly marked, numbered rack-mount spaces.

Image: Top cover with cable grommet holes and numbered rack-mount spaces for easy equipment installation.

Step 3: Install Rack Shelves and Shelf Stops

Insert the two ventilated rack shelves into the desired U-positions. Secure them using the provided shelf stops and rack shelf back supports to prevent equipment from sliding and enhance stability.

Assembled rack with installed shelves, showing anti-slip shelf stops and rack shelf back supports for enhanced stability.

Image: Rack with shelves, highlighting anti-slip shelf stops and back supports for secure equipment placement.

Step 4: Choose Mounting Option (Floor Standing or Wall Mounted)

The rack can be used as a floor-standing unit or mounted to a wall. For floor standing, attach the leveling feet to the bottom of the rack. For wall mounting, use the provided mounting hole drilling template and M5*30 wall mounting screws. Ensure proper reinforcement for wall mounting, especially for heavier loads.

Image showing the mounting hole drilling template and the assembled rack, illustrating versatile mounting options.

Image: Mounting hole drilling template for easy wall installation and a view of the assembled rack.

Diagram illustrating ground-mounted load-bearing capacity of 260lbs and wall-mounted load-bearing capacity of 130lbs.

Image: Load capacity details for both ground-mounted (260lbs) and wall-mounted (130lbs) configurations.

操作和使用

Once assembled, the Tecmojo 12U Open Frame Network Rack provides a robust solution for organizing your 19-inch rack-mountable equipment. The open frame design promotes excellent airflow, crucial for preventing overheating of network and AV devices.

  • 設備安裝: Mount your 19-inch networking, audio, and video devices directly into the rack using the provided equipment mounting screws. The numbered U-spaces assist in precise placement.
  • 纜線管理: Utilize the top panel's grommet holes and included velcro straps to route and secure cables, maintaining a tidy and efficient setup.
  • 貨架利用率: Place non-rack-mountable equipment, such as modems, routers, or small servers, on the ventilated shelves. Use the anti-slip shelf stops to keep them secure.
Example setup of a 12U rack with various networking and AV equipment installed, showcasing organized cables and devices.

圖:前任ample of a fully equipped Tecmojo 12U rack with networking and AV gear, demonstrating effective organization.

維護

To ensure the longevity and optimal performance of your Tecmojo Network Rack and the equipment housed within it, regular maintenance is recommended:

  • 打掃: Periodically wipe down the rack with a soft, dry cloth to remove dust. For stubborn dirt, a slightly damp 可以使用布,然後立即擦乾。
  • 螺絲緊固度: Over time, screws may loosen. Periodically check all assembly screws and equipment mounting screws to ensure they are securely tightened.
  • 纜線管理: Review cable routing and re-secure any loose cables to prevent strain and maintain airflow.
  • 通風: Ensure that the open frame design is not obstructed, allowing for maximum airflow to prevent equipment overheating.

故障排除

如果在組裝或使用過程中遇到問題,請考慮以下幾點:

  • 貨架穩定性: If the rack feels wobbly, re-check all screws for tightness. For floor-standing units, ensure leveling feet are properly adjusted on an even surface. For wall-mounted units, verify secure attachment to wall studs or appropriate anchors.
  • Equipment Fit: Ensure your equipment is 19-inch rack-mountable. If a device does not fit, check its dimensions against standard rack unit measurements.
  • 缺少的部分: Refer to the "Package Contents" section. If any parts are missing, contact Tecmojo customer support.
  • 設備過熱: Ensure adequate space around equipment for airflow. The open frame design is intended to maximize ventilation; avoid blocking vents on devices.

保固和支持

For warranty information, technical support, or to inquire about replacement parts, please visit the official Tecmojo web請造訪其網站或直接聯絡客服。請保留購買收據,以便進行保固索賠。

註:本產品來自小型企業品牌。

© 2024 Tecmojo. All rights reserved.